1" Digital Diesel Flow Meter  Electronic flow meter. 1" BSPF ports, 20-180L/min.  - Only suitable with diesel or biodiesel up to B30. - Display & totaliser shows up to 9999.9 litres. - 20 – 180L/min. 1” BSPF ports. Max. pressure 45 psi (3 bar). - Accuracy +/- 2.5%. Aluminium housing. - Designed to fit inline with delivery hose or pipework. - Operating temp -10°C to 60°C.

1" Digital Diesel Flow Meter Electronic flow meter. 1" BSPF ports, 20-180L/min. - Only suitable with diesel or biodiesel up to B30. - Display & totaliser shows up to 9999.9 litres. - 20 – 180L/min. 1” BSPF ports. Max. pressure 45 psi (3 bar). - Accuracy +/- 2.5%. Aluminium housing. - Designed to fit inline with delivery hose or pipework. - Operating temp -10°C to 60°C.

GPI 1" Electronic Meter  4 digit electronic flow meter. 1" BSPF ports, 10-100L/min, 4 digit register.  - Only suitable for use with diesel or biodiesel up to B30. - Display & totaliser shows up to 9999 litres. - 10 - 100L/min. 1” BSPF ports. Max. pressure 290 psi (20 bar). - Accuracy +/- 2.5%. Aluminium housing. - Designed to fit in line with the delivery hose or pipework. - Turbine flowmeter. Weight 340g. - Powered by 2 x AAA batteries (Approx life 9000 hours).

GPI 1" Electronic Meter 4 digit electronic flow meter. 1" BSPF ports, 10-100L/min, 4 digit register. - Only suitable for use with diesel or biodiesel up to B30. - Display & totaliser shows up to 9999 litres. - 10 - 100L/min. 1” BSPF ports. Max. pressure 290 psi (20 bar). - Accuracy +/- 2.5%. Aluminium housing. - Designed to fit in line with the delivery hose or pipework. - Turbine flowmeter. Weight 340g. - Powered by 2 x AAA batteries (Approx life 9000 hours).

Macnaught 1" Oval Gear  DM100 4 digit Oval gear meter. 3-80L/min. 1" BSPF ports. 4 digit register and 6 digit totaliser.  • Only suitable with diesel, biodiesel, ethanol, methanol & oils up to 1000 cps. Oval gear meter shows up to 999.9 litres • Max. pressure 145 psi (10 bar). • Accuracy +/- 1%. Low flow resistance. • Aluminium body. Supplied with a mesh strainer. • Front face can be rotated in 90 degree increments. • Max. temperature 80°C (176°F).

Macnaught 1" Oval Gear DM100 4 digit Oval gear meter. 3-80L/min. 1" BSPF ports. 4 digit register and 6 digit totaliser. • Only suitable with diesel, biodiesel, ethanol, methanol & oils up to 1000 cps. Oval gear meter shows up to 999.9 litres • Max. pressure 145 psi (10 bar). • Accuracy +/- 1%. Low flow resistance. • Aluminium body. Supplied with a mesh strainer. • Front face can be rotated in 90 degree increments. • Max. temperature 80°C (176°F).

Fill-Rite 900 Series 1½" Digital Meter  Electronic Meter. 1.5" BSPF ports, 25-150L/min max. flow rate, 4 digit register and 7 digit totaliser.  - Only suitable with diesel or biodiesel up to B20. - Robust nutating disc flow meter, shows up to 9999 litres. - 25 - 150L/min. 1.5” BSPF ports. Weight 2.9kg. - Max. pressure 50 psi (3.5 bar). Aluminium housing. - Accuracy +/- 1.25% (must be calibrated on site before use). - Electronic display with 4 digit register. 7 digit totaliser.

Fill-Rite 900 Series 1½" Digital Meter Electronic Meter. 1.5" BSPF ports, 25-150L/min max. flow rate, 4 digit register and 7 digit totaliser. - Only suitable with diesel or biodiesel up to B20. - Robust nutating disc flow meter, shows up to 9999 litres. - 25 - 150L/min. 1.5” BSPF ports. Weight 2.9kg. - Max. pressure 50 psi (3.5 bar). Aluminium housing. - Accuracy +/- 1.25% (must be calibrated on site before use). - Electronic display with 4 digit register. 7 digit totaliser.

Hytek 3" Professional Bulk Meter  Professional Bulk Meter. 75-750L/min, 3" BSPT flanges, 60 mesh/240 micron, 5 digit resettable totaliser.  • Only suitable with light lube oils, petrol, diesel or biodiesel up to B30. Viscosity 30SSU - 1,500,000SSU. • Positive displacement bulk meter includes: Mechanical register. • Air eliminator. • Max. pressure 150 psi (10 bar). • Accuracy +/- 0.3%. • Aluminium body. Viton seals. • (BM.3) 3” flow rate 75-750L/min. • Dimensions 53cm W x 44cm D x 50cm H.

Hytek 3" Professional Bulk Meter Professional Bulk Meter. 75-750L/min, 3" BSPT flanges, 60 mesh/240 micron, 5 digit resettable totaliser. • Only suitable with light lube oils, petrol, diesel or biodiesel up to B30. Viscosity 30SSU - 1,500,000SSU. • Positive displacement bulk meter includes: Mechanical register. • Air eliminator. • Max. pressure 150 psi (10 bar). • Accuracy +/- 0.3%. • Aluminium body. Viton seals. • (BM.3) 3” flow rate 75-750L/min. • Dimensions 53cm W x 44cm D x 50cm H.

1" Piusi Diesel Flow Meter  3 Digit flow meter. 1" BSPF ports, 20-120L/min. 3 digit register, 6 digit non-resettable totaliser.  • Suitable for use with diesel. Version for oil/B100 (K330). • Robust nutating disc flow meter shows up to 9999 litres. • Max. pressure 142 psi (10 bar). • Accuracy of +/- 2% with adjustable calibration. • Aluminium housing & cover.  • Front face can be rotated in 90 degree increments.

1" Piusi Diesel Flow Meter 3 Digit flow meter. 1" BSPF ports, 20-120L/min. 3 digit register, 6 digit non-resettable totaliser. • Suitable for use with diesel. Version for oil/B100 (K330). • Robust nutating disc flow meter shows up to 9999 litres. • Max. pressure 142 psi (10 bar). • Accuracy of +/- 2% with adjustable calibration. • Aluminium housing & cover. • Front face can be rotated in 90 degree increments.

Hytek Bulk Meter Register  Bulk Meter Register. 5 digit resettable register, 8 digit totaliser. Cover cast aluminium.  • Mechanical register. • Resettable via right hand register knob. • Fits positive displacement bulk meters. • Wheels, pinions & clutch made from acetal resin.

Hytek Bulk Meter Register Bulk Meter Register. 5 digit resettable register, 8 digit totaliser. Cover cast aluminium. • Mechanical register. • Resettable via right hand register knob. • Fits positive displacement bulk meters. • Wheels, pinions & clutch made from acetal resin.

Fill-Rite 1½" Flow Meter with Pulser  4 Digit flow meter with pulser. 1 1/2" BSPF ports. 25-150L/min. 4 digit register, 8 digit non-resettable totaliser. 10:1 pulser fitted.  • Only suitable for use with diesel or biodiesel up to B30. • Robust nutating disc flow meter shows up to 9999 litres. • 11/2" BSPF ports. Max. pressure 50 psi (3.5 bar). • Accuracy of +/- 2% with adjustable calibration. Buna-N seals. • Aluminium housing. Nickel plated version available.

Fill-Rite 1½" Flow Meter with Pulser 4 Digit flow meter with pulser. 1 1/2" BSPF ports. 25-150L/min. 4 digit register, 8 digit non-resettable totaliser. 10:1 pulser fitted. • Only suitable for use with diesel or biodiesel up to B30. • Robust nutating disc flow meter shows up to 9999 litres. • 11/2" BSPF ports. Max. pressure 50 psi (3.5 bar). • Accuracy of +/- 2% with adjustable calibration. Buna-N seals. • Aluminium housing. Nickel plated version available.

Piusi ½" Oval Gear Meter  K400 oval gear meter. 1-30L/min. 1/2" BSPF ports. Electronic display with 5 digit register.  • Only suitable for use with diesel, oils & antifreeze. • IP55 rating. • Robust oval gear type meter shows 9999 litres. • Accuracy +/ -0.5%. Max. pressure 994 psi (70 bar). • Aluminium construction. Weight 0.5kg. • Powered by 2 x AAA batteries.

Piusi ½" Oval Gear Meter K400 oval gear meter. 1-30L/min. 1/2" BSPF ports. Electronic display with 5 digit register. • Only suitable for use with diesel, oils & antifreeze. • IP55 rating. • Robust oval gear type meter shows 9999 litres. • Accuracy +/ -0.5%. Max. pressure 994 psi (70 bar). • Aluminium construction. Weight 0.5kg. • Powered by 2 x AAA batteries.

Fill-Rite 1" Diesel Flow Meter & Strainer  3 Digit flow meter with integral inlet strainer. 1" BSPF ports. 19-75L/min. 3 d	igit register, 6 digit non-resettable totaliser. 400 micron strainer.  • Only suitable for use with diesel or biodiesel up to B30. • Robust nutating disc flow meter shows up to 999 litres. • 19 - 75L/min. Max. pressure 50 psi (3.5 bar). • Accuracy of +/- 2% with adjustable calibration. • Option 10:1 pulser, fitted to meter on request (PULS10).

Fill-Rite 1" Diesel Flow Meter & Strainer 3 Digit flow meter with integral inlet strainer. 1" BSPF ports. 19-75L/min. 3 d igit register, 6 digit non-resettable totaliser. 400 micron strainer. • Only suitable for use with diesel or biodiesel up to B30. • Robust nutating disc flow meter shows up to 999 litres. • 19 - 75L/min. Max. pressure 50 psi (3.5 bar). • Accuracy of +/- 2% with adjustable calibration. • Option 10:1 pulser, fitted to meter on request (PULS10).